Steam generator tube inspection with an axial probe
Summary
Specimens
Four steam generator tubes made in inconel (conductivity of 1 MS.m-1 and a relative permeability of 1) are inspected with a bobbin probe. The tubes have an external diameter of 22.22 mm, an internal radius of 9.84 mm, a thickness of 1.27 mm and they measure 50 mm length.

Probe
The axial probe is made out of two identical cylindrical coils, with an internal diameter of 15.66 mm, an external diameter of 17 mm and a width of 2 mm. The gap between both coils measures 0.5 mm. The acquisition is carried out at a frequency of 100 kHz in a differential mode.

Defects
Each of the fhe four tubes contain a different defect:
- A calibration defect: an external groove at 40 % of the tube thickness, 360 ° around the tube and 1 mm long.

- An external and longitudinal notch of 6 mm length, 0.1 mm thickness, and a depth of 52 % of the tube wall.

- An external and longitudinal notch of 10 mm length, 0.1 mm thickness, and a depth 54 % of the tube.

- A transverse through wall notch, 82 degrees aperture and 0.1 mm length.

Comparisons between Experiment and Simulation
For the three studied defects, the Lissajous curves are drawn and the amplitudes, phases, real and imaginary parts as a function of the scanning are represented on the figures below. A good agreement between experiment and simulation is observed.
Then, the amplitude and phase values are gathered in a table and the difference between acquisitions and CIVA simulations are calculated. The low discrepancies values confirm the good agreement between CIVA and experiments.
But first of all, simulated and experimental Lissajous curves related to the calibration defect are superimposed her below.
External groove at 40% – calibration defect


An external and longitudinal notch of 6 mm length



An external and longitudinal notch of 10 mm length



A transversal through wall notch, 82 degrees aperture



Go to TUBE INSPECTION WITH A ROTATING PROBE
Go back to TUBES